Skip to content

Provider usage readers reference

This page is the operator’s field reference for the usage readers. The user-facing vocabulary (class, scope, freshness, the chat rows) is on Provider usage reference.

The provider table in sc-provider-quota-calendar is the ONE source: each declaration names a reader, the providers it reads, its class, where it reads, its ladder position and its ToS note. A reader that is declared but not implemented in a build is reported as implemented: false — the console never implies a reader the build does not ship.

Ladder Meaning
official An official provider endpoint
headers Rate-limit headers on traffic we already sent
harness_local The vendor’s own client inside the harness
back_door A vendor-client endpoint called with the credential we already hold
own_metering Our own arithmetic, always class estimate
definition A window declaration with no observation

A reader never issues a completion to obtain a reading. A paid probe is never issued.

Store Scope Default Written by
provider_usage_reader_switches Instance-wide, one row per reader enabled (an absent row) PUT /api/operator/v1/usage-readers/{reader}
usage_alert_thresholds (instance setting) Instance-wide 80,95 PUT /api/operator/v1/usage-alert-thresholds
provider_usage_reader_state One row per (credential, reader) created on first attempt the ingest path
provider_usage_threshold_notices One row per announced crossing — the announcing sweep

An absent switch row is a decision, not a gap: the readers are ON unless an operator says otherwise. That is why the store never seeds rows.

The unique key of provider_usage_threshold_notices is (credential_id, credential_kind, window_type, scope, threshold_percent, window_anchor). window_anchor is the window INSTANCE: the provider’s stated reset, else the window’s own start. The announcing path inserts with ON CONFLICT DO NOTHING and announces only when its own insert landed, so:

  • a reader tick, a task-boundary read, a refresh and N replicas all observing one crossing produce exactly ONE notice;
  • a new window, or a reset the provider moves, re-arms both thresholds;
  • a claim is pruned after the reading retention (90 days, owner decision D8).
Value Built-in Operator value Where
Notification thresholds 80,95 yes usage_alert_thresholds instance setting
Reader switch on yes provider_usage_reader_switches
Read-through minimum interval, backoff, single-flight owned by the read-through seam (S4) per its own settings logged by that seam
Reading retention 90 days — migration 848’s retention function

Every value that paces or blocks is settable from outside, and one boot log line names the values in force.

Surface Bar
GET /api/workspaces/{id}/usage/manage Workspace admin
POST /api/workspaces/{id}/usage/refresh Workspace admin
usage.get (MCP) Workspace admin, resolved as the human who launched the session’s task
/api/operator/v1/usage-readers* Operator credential
/api/operator/v1/usage-alert-thresholds Operator credential

A member cannot spend a reader’s own rate limit by pressing refresh, and a project credential can never reach a workspace usage read.